The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated.
At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table:
hospital incinerator...
Model YD-30 Mobile Type Picture Burning Rate Average 30 kgs/hour Feed Capacity Average 60 kgs/feeding Chamber Main Body Stainless Steel Mobile Function With Wheel and Brake Primary Combustion Chamber 280 Liters Secondary Combustion Chamber 150 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 1.5 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 13.3 kg/hour Internal Dimensions 80 x 60...
chemical agents to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water solution,
azotic (nitric) acid vapour with concentration up to 1.1 kg/m3;
2. neutralization method: thermal decomposition;
3. neutralization temperature: +800?C to +1200?C;
4. ...
BURNING RATE : -100-150kgs per hour
MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION )
MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION )
SECONDARY BURNING CAPACITY : COMPULSORY
DENSITY INSULATION : 50 mm high
Refractory capacity : min 114mm
HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C
AVEARGE BURN OUT TIME : MAXIMUM 3HRS
FUEL TYPE : FUEL OIL ( DIESEL )
FUEL CONSUMPTION IN LTRS/HR : average 14
RESIDNECY...
Model A600, crematorium manufacturers Internal Dimensions 130 x 70 x 65cm Suit for Animal Cat – yes Dog – yes Pig – no Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 units Oil Tank (if oil fuel): 200Liters dog cremation urns Model A600 Picture ...
Mobile Containerized Waste Incinerators pets or human cremation emergency use Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x 100cm (primary chamber) External Dimensions 290 x 200 x 170cm...
medical waste diesel incinerator Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary...
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity. Model YD-150 Picture Burning Rate Average 150 kgs/hour Feed...
Incinerate: medical waste and general waste Capacity to burn waste:
400-500kg/hr
Fuel: Diesel
Fuel Consumption: 10 liters/hr maximum
Incineration temperature: 950-1300 degrees centigrade
Casing: thick (min 5mm) stainless steel casing and fully insulated to
withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz
high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for...