BURNING RATE: -100 -150 kgs per hr
MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)
MAX OPERATING TEMPERATURE LEVEL LEVEL: 1000-1200 oC (AFTER HEATING UNIT BURNING)
SECONDARY MELTING ABILITY: COMPULSORY
THICKNESS INSULATION: 50 mm high
Refractory ability: mins 114mm
STURDY REFRACTING LINING TO WITHSATND 17500C
AVEARGE WEAR OUT TIME: MAXIMUM 3HRS
GAS KIND: GAS OIL (DIESEL)
GAS CONSUMPTION IN LTRS/HR: average 14
RESIDNECY TIME IN...
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity. Layout YD-150 Image Burning Rate Normal 150 kgs/hour Feed...
General specifications of a 100 kg/hr incinerator No.
Description
Parameter value
model
HICLOVER YD100 1
Machine working mode
Oil + Power
Oil + Power 2
Voltage
220V C 3 phase or 1 phase
220V 1P 3
Oil consumption (lit/hr)
Average 25-32 lit/hr/chamber
Average 33Liters/hour/total incinerator 3 burners 6
Incineration rate
100 kg/hr = 400-600 kg/8hr
average 100kgs per hour 7
Feed mode
Manual
manual 8
Primary combustion rate
1000 lit
1080...
the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a...
● Able to burn 25-30kg per hour
● Consist of two chambers to ensure significant reduction in emission
● Be capable of temperature in range of 800c to 1000c
● Low maintenance design
● Must be Diesel fuelled
● Need more than 15amp 220- 250V power
● kW Consumption power consumption to be stated
● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste
● Solid...
Items/Model TS50M Picture Melt Rate Typical 50 kg/hour Feed Capacity Average 50-150 per feeding Control Setting PLC( Programmable Thinking Controller Incinerator) Combustion Chamber 450L Internal Measurements 75x75x80cm Extra Chamber 225L Smoke Filter Chamber Yes Feed Setting Manual Feeding Voltage 220V Power 0.5 Kw Oil Use (kg/hour) Average 13.3 Gas Use (N.G, m3n/Hour) Ordinary 16 Gas Intake (L.P.G, m3n/Hour) Normal 11.7 Temperature Level...
Style for Pets Cremation Service Movable system & & & & Vehicle. Door Independent Placement for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Design A1500 Image Burning Rate Typical 150 kgs/hour Feed Capacity Standard 350 kgs/feeding Main Burning Chamber 1500 Liters Second Burning Chamber 500 Litres Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Setting...