?Incinerate minimum 80kg/hr X 12 hrs per day
?Disposal of both non-hazardous and hazardous waste streams (per waste inventory)
?Mobile Unit (Skid mounted preference with lifting points)
Design/Specifications
?Incinerators must have a secondary combustion chamber with a minimum temperature range of 900c
?Liquid waste streams shall be incinerated by an appropriate liquid injection system
?The incinerators will be installed with visual alarms to...
Class 2 Industrial Incinerators
Class 2A: Commercial
Incinerators for the disposal of waste that contains hazardous, potential hazardous and bio-medical waste where the
operator exceeds 100 Kg/day. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h)
Fully automatic computer multi control system.
Fuel Options- Diesel and natural gas, electricity
Wasted fuel- >12L/h
The incinerator should...
Ensure flame contact with all gases is achieved. –yes
Ensure residence time is not less than two (2) seconds. –yes
Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.—1000-1200 oC
Ensure the oxygen content of the emitted gases is not less than 11%.–yes
Ensure both primary and the combustion temperatures are maintained until all waste has...
Combustion Efficiency 99.99%
Retention time Of the flow gases not less than 2 Sec in the hot portion.
Excess Oxygen concentration Of primary combustion chamber 3-6% max.
Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and
with highly temp. resistance. Not less than 1400 C for the first combustion chamber, and not less...
We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr,
10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind
(including hospital wastes) per day or per hour. Should it be with no smoke, no fumes, no odour (smell), no dust, no
emission of solid particles and with least minimum pollution (within national and international...
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical...
1.Solidifier (Fluid waste disposal product)
Liquid Waste Solidifier for Water Based
Special Features of Solidifier
2lb bottle
Effectively solidifies potentially serious infectious waste quickly
Quickly8 penetrates to solidify blood and body fluid to convert Gels in seconds
No shaking required
Retrains solidity to prevent spills and leaks for safe and easy bagging and easy transport to disposal.
Concentrated formula: one...
combustion chamber and one
flue gas afterburning chamber. The incinerator must be able to meet the following parameters:
1.Treatment capacity of: a) 50 kg waste per hour.
2.Temperature: Main combustion chamber up to 850°C, and in the second chamber > = 1,100 °C
3.Retention Time: 2 seconds in the second chamber
The furnace (including secondary combustion chambers etc.) dimensions must be large enough to provide...
Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum.
Capacity: Up to 12 kg/h
Chamber size: >150 liters
Material: Stainless steel
Temperature: 134 °C
Further information:
Minimum autoclave chamber size shall be 150 liters and...