manufacturer of ha zardous waste incinerator in china

?Incinerate minimum 80kg/hr X 12 hrs per day ?Disposal of both non-hazardous and hazardous waste streams (per waste inventory) ?Mobile Unit (Skid mounted preference with lifting points) Design/Specifications ?Incinerators must have a secondary combustion chamber with a minimum temperature range of 900c ?Liquid waste streams shall be incinerated by an appropriate liquid injection system ?The incinerators will be installed with visual alarms to...

incinerators animal

Class 2          Industrial Incinerators Class 2A:    Commercial Incinerators for the disposal of waste that contains hazardous, potential hazardous and bio-medical waste where the operator exceeds 100 Kg/day. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h) Fully automatic computer multi control system. Fuel Options- Diesel and natural gas, electricity Wasted fuel- >12L/h The incinerator should...

medical waste incinerators china

Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.—1000-1200 oC   Ensure the oxygen content of the emitted gases is not less than 11%.–yes Ensure both primary and the combustion temperatures are maintained until all waste has...

incineration in china

Combustion Efficiency     99.99% Retention time    Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration  Of primary combustion chamber 3-6% max. Refractory    The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp. resistance. Not less than 1400 C for the first combustion chamber, and not less...

medical incinerator 20kg

We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr, 10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind (including hospital wastes) per day or per hour. Should it be with no smoke, no fumes, no odour (smell), no dust, no emission of solid particles and with least minimum pollution (within national and international...

About Hiclover Medical Enviromental

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical...

incinerator suppliers

1.Solidifier (Fluid waste disposal product)   Liquid Waste Solidifier for Water Based Special Features of Solidifier 2lb bottle Effectively solidifies potentially serious infectious waste quickly Quickly8 penetrates to solidify blood and body fluid to convert Gels in seconds No shaking required Retrains solidity to prevent spills and leaks for safe and easy bagging and easy transport to disposal. Concentrated formula: one...

pet crematory equipment

Physical /Chemical Characteristics: Boiling Point (_F) :  N/A                     Appearance & Odor: Off white, odorless Vapor Pressure(mm Hg): N/A        Volatiles (% by weight): N/A Vapor Density (Air =1) :N/A         Evaporation Rate )n-butylacetate=1): N/A HMIS...

incinerators 150 kg per hour

combustion chamber and one flue gas afterburning chamber. The incinerator must be able to meet the following parameters:   1.Treatment capacity of: a) 50 kg waste per hour.   2.Temperature: Main combustion chamber up to 850°C, and in the second chamber > = 1,100 °C   3.Retention Time: 2 seconds in the second chamber   The furnace (including secondary combustion chambers etc.) dimensions must be large enough to provide...

incinerators 300 kg per hour

Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum.   Capacity:      Up to 12 kg/h   Chamber size:      >150 liters   Material:       Stainless steel   Temperature:       134 °C   Further information:   Minimum autoclave chamber size shall be 150 liters and...